Trouble Ticket Number |
DTS2024103121064 |
|---|---|
Symptom |
In an SD-WAN scenario, when an Ethernet physical interface is Up and its duplex mode is switched, no alarm or event is generated and sent to the controller. |
Condition |
In an SD-WAN scenario, the duplex mode of an Ethernet physical interface is switched when the interface is Up. |
Impact |
No alarm is generated and reported to the controller when the duplex mode of an interface is switched, and no event is generated and reported to the controller when an interface works in half-duplex mode. |
Severity |
Minor |
Root Cause |
The interface alarm reporting process and event reporting process are improper. |
Solution |
1. An alarm is reported when the duplex mode of an interface is switched. 2. Events are reported every 30 minutes when an interface works in half-duplex mode. |
Solution Impact |
None |
Problem Resolved in |
V300R023C00SPC100 |
Involved Models |
AR600, AR6100, AR6200, AR6300 |
Precaution |
If real-time interface reporting is enabled, event reporting is suspended. After real-time interface reporting is disabled, event reporting is resumed. |